The daily maintenance of the bag filter is divided into 8 steps
Release time:
2023-01-16 09:18
【Abstract】:
As a basic dust removal equipment, cloth bag dust collector needs to be treated seriously for its daily maintenance work, so as to prolong its service life, play the utility of dust removal and smoke removal for a longer time, and create value for enterprises.
As a basic dust removal equipment, cloth bag dust collector needs to be treated seriously for its daily maintenance work, so as to prolong its service life, play the utility of dust removal and smoke removal for a longer time, and create value for enterprises.
1. During normal operation, it is recommended to record the pressure difference of the dust removal chamber and the inlet temperature of the dust removal chamber once every hour. If any abnormal situation occurs, measures should be taken immediately to solve it. For example, Customer D in Huishan District, Wuxi strictly implemented and managed the record, the pulse bag dust collector was used smoothly, and the flue gas was controlled within a reasonable range.
2, bag dust collector to check regularly whether the dust collector electrical and gas components are running normally; Regularly check the compressed air quality for pneumatic components to ensure that the compressed air is dry and clean.
3. Check the dust discharge situation of the dust hopper of the dust collector once per work team of the bag dust collector, and make sure that the ash accumulation of the dust hopper does not exceed one third of the height of the dust hopper.
4. The bag dust collector should be monitored at any time. If ash is found in the chimney, it indicates that the flue gas is short circuit, and the phenomenon of bag dropping or bag breaking occurs, it should be investigated and treated in time.
5. Check the pressure of compressed air for pulse frequently to ensure that the dust removal pressure of the dust collector is within the standard range.
6. Bag dust collector should check and maintain the position of the pulse spray pipe regularly to avoid the deviation of the pulse nozzle from the center of the filter bag due to the loosening of the pulse spray pipe, the removal of the position and the loss of the connection, resulting in the damage of the filter bag.
7. Check regularly whether there is dust blockage in the pipe of each chamber of the dust collector, and whether the flue gas baffle is in good condition.
8. Check the sealing condition of the separator door of the dust collector regularly to ensure that all the sealing conditions are good and will not leak.